Miscellaneous Projects
Sensor Calibration System
Client:
ASC AVCAN Systems Corp. - Vancouver, BC
Client's Request:
To provide an easy solution for aligning the axis of two
cameras with the axis of a fibre optic rate sensor.
Overview of KLN's Contribution:
Design of an alignement procedure and design and construction
of all necessary jigs permitting to laterally and rotationally
align the axis of the two cameras with the axis of a fibre
optic rate sensor.
Detailed Outcome:
An innovative combination between a modified plumb bob, a laser
pointer, a precise geometrical target (visible for the daylight
and the infrared camera), as well as a precisely orthogonally
moving swivel mount yielded the tools necessary to align the
relevant system components.
The setup as indicated above yielded a system accuracy well
sufficient to support the client's accuracy requirements.
Further, it is easily adaptable to support different camera
and sensor configurations.